omron · 2 стр.

Руководство по эксплуатации Safety F3SG SR PG — Системы безопасности (EN)

Оригинальное название: Safety F3SG SR PG FAQs EN 202007 LC 080

Читать онлайн

Похожие инструкции

Содержание

Текст документа

F3SG-SR/PG Frequently Asked Questions

NO: LC-080 PRODUCT: F3SG-SR/PG DATE: July 2020 TYPE: FAQ F3SG-SR/PG Frequently Asked Questions a. The –F stands for flexible height models. These models are 40mm increments from the previous length model. For example, F3SG-4SRA0160-14 does not have a –F, but the next height model, F3SG-4SRA0200-14-F does. There is no difference in performance between these two models. 2) Do you need the Intelligent Tap (F39-SGIT-IL3) to program? 1) What does the –F mean on certain models? a. Yes, the Intelligent Tap is required to program advanced features of the F3SG- SR/PG. The features can be enabled and programmed via DIP switches or through the SD Manager 3 PC software.

DIP switch enabled features are as follows: i. Interlock ii. Pre-Reset iii. External Device Monitoring (EDM) iv. Fixed Blanking v. Floating Blanking vi. Operating range selection 3) Does the Intelligent Tap need to be connected all the time to the F3SG-SR/PG for it to work? a. No. The Intelligent Tap can be used to program the F3SG-SR/PG and once the program is uploaded to the light curtain, it can be removed. 4) Are there any changes to the DIP Switch to restore the program from the Intelligent Tap to a replacement F3SG-SR/PG or new F3SG-SR/PG with the same program? a. No.

The default DIP switch settings will automatically send the Intelligent Tap stored program to the F3SG-SR/PG it is connected. 5) What is the difference between machine guarding and perimeter access safety light curtains? a. Machine guarding safety light curtains help protect operators from a point of intrusion, where perimeter access safety light curtains restrict the entrance into an area where a large machine is working.

Стр. 1

F3SG-SR/PG Frequently Asked Questions

6) What is the difference between the F3SG-SRA and F3SG-SRB models? a. The only difference is the SRA model has the ABIs and a vibration sensor. Otherwise, the SRA and SRB can perform the same functions (muting, blanking, reduced resolution, EDM, etc.) 7) Do you need the Intelligent Tap connected to show ABIs on both emitter and receiver? a. No, as long as you connect the F3SG-SRA emitter and receiver via wired synchronization, you will see ABIs on both sides. If you use optical synchronization, you will only see ABIs on the receiver. 8) Does Scan B come with every purchase of an F3SG-SR or are they sold separately? a. 2 Scan B end caps come with every purchase of the F3SG-SR.

9) To utilize IO-Link, do you need the Intelligent Tap? a. Yes, in order to use the IO-Link communication capability, you must have the Intelligent Tap installed at all times. 10) Do we have conversion cables for existing installations? a. Yes, we have conversion cables for F3SJ-B/A, F3SG-RE, and MS48. If you do not see your product that you are converting from on the list above, please contact your local Omron Account Manager to see if we have a cable for you. 11) Do you program the F3SG-RA and SR with the same software? a. No. The F3SG-SR is programmed using the new SD Manager 3. The F3SG-RA uses the SD Manager 2.

12) Do I need the Intelligent Tap to be able to connect to the F3SG-SR via Bluetooth? a. Yes, the Bluetooth module F39-SGBT plugs directly into the Intelligent Tap. 13) Can the F3SG-PG be used in a cascaded configuration? a. No, the F3SG-PG does not support cascaded configuration. 14) Can the F3SG-SR-K be used in a cascaded configuration? a. No, the F3SG-SR-K does not support cascaded configuration. 15) Does it matter what type of through beam or photoelectric sensor I use when muting? a. Yes. You must ensure that the output used on the light curtain is the same as the sensor (for example, if you are using a PNP sensor, make sure the light curtain is also operating with a PNP output).

Specifications and prices in this product news are as of the issue date and are subject to change without notice. Only main changes in specifications are described in this document. Please be sure to read the relevant catalogs, product specifications, instructions, and manuals for precautions and necessary information when using products