MIL MIL-HDBK-683(AT) — MIL-HDBK-683(AT) Statistical Process Control (SPC) Handbook - Implementation & Evaluation PDF (EN)

Downloaded from https://www.everyspec.com MIkHDBK-663(AT ) collection and inqpction of the parts. If this does not occur on a real time basis, the result is the control charta are merely quality reporte with control limits and not truly real time process control. Other ccmnitments required to ensure continuity of S= data in the automated data collection environment inchde bLV~ back-up equi~t available to replace equipment down for maintenance and hIW~ multiple copies of the selected software available to counteract the inevitable ~~ f1- diak- Data input errors on a computer or a dedicated SPC analyzer are a potential problem source when using software controlled WC.

Wee errors are generally self-correcting in a uystem with good overall design, with the greatest potential for error coming in the fom of missed identification of out of control points. The remainder of this chapter deacrihea a minimum aet of characteristics to consider when selecting SPC software. The essential features are the ability to enter and display data on a real time basis and the ability to display data in a control chart format. All other features are desirable to different degrees depending on the particular environment in which the SFC system is o~rating. 6-4 ibaxMah- 6.4.1 .

To minimize the number of out of control parts produced by a process, the WC data must be available immediately after production of the parts. This real time emphasis characterizes all Successful WC programs. Processes allowed to operate in an out of control condition will quickly demoralize the production work force and undermine the credibility of the entire SPC philoso~. Therefore, a primary criteria for WC software selection is the ability of the software to be easily started, operated continuously during production, and capable of rapid data entry, computation of the appropriate data points and display of the calculated information.

Software which ~ires complicated start-up procedures, a system operator for accesa or cauplicated graphics add-on programs to display data should be used only in specialized situations where these features shall not degrade the prima objective of real time data availability. Graphic data display is essential if runs, trends and other out of control indicators are to be easily recognized. It is not enough to have the software detexmine that a particular point is in or out of control based on ~-~~md criteria.

The trained statistician or engineer monitoring the Proceaaeashouldbe able w spot a new pattern wh%ch demands attention when looking at a good gra~ical display more readily than when looking t- tabulated or quasi-printouts. 74 Am&w n-h=--- ---- __w. . -