S UPER S ERVER 6011L Manual Installing the Chassis Rails: Position the fixed chassis rail sections you just removed along the side of the 6011L chassis making sure the five screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack. Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing. Figure 2-2. Installing Chassis Rails Installing the Rack Rails: Determine where you want to place the SuperServer 6011L in the rack. rail/sliding rail guide assemblies at the desired location in the rack, (See Rack and Server Precautions in Section 2-3.) Position the fixed rack keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the 2-4