4-2 Function Mode 4 Functions 4-95 Register No. Function name Parameter No. R/W Function Monitor or data range Resolution 1020h FV start frequency A011 R/W 0 to 4000 0.1 [Hz] 1022h FV end frequency A012 R/W 0 to 4000 0.1 [Hz] 1023h FV start ratio A013 R/W 0 to 100 1 [%] 1024h FV end ratio A014 R/W 0 to 100 1 [%] 1025h FV start selection A015 R/W 00: Start frequency A011 01:

0 Hz ⎯ 1026h FV, FI sampling A016 R/W 1 to 17 ⎯ 1029h Multi-step speed reference 0 A020 R/W 0.0/Starting frequency to 4000 0.1 [Hz] 150Fh 2nd multi-step speed reference 0 A220 R/W 0.0/Starting frequency to 4000 0.1 [Hz] 102Bh Multi-step speed reference 1 A021 R/W 0.0/Starting frequency to 4000 0.1 [Hz] 102Dh Multi-step speed reference 2 A022 R/W 102Fh Multi-step speed reference 3 A023 R/W 1031h Multi-step speed reference 4 A024 R/W 1033h Multi-step speed reference 5 A025 R/W 1035h Multi-step speed reference 6 A026 R/W 1037h Multi-step speed reference 7 A027 R/W 1039h Multi-step speed reference 8 A028 R/W 103Bh Multi-step speed reference 9 A029 R/W 103Dh Multi-step speed reference 10 A030 R/W 103Fh Multi-step speed reference 11 A031 R/W 1041h Multi-step speed reference 12 A032 R/W 1043h Multi-step speed reference 13 A033 R/W 1045h Multi-step speed reference 14 A034 R/W 1047h Multi-step speed reference 15 A035 R/W 1048h Jogging frequency A038 R/W 0 to 999 0.01 [Hz] 1049h Jogging stop selection A039 R/W 00:

Free-run stop 01: Deceleration stop 02: DC injection braking stop ⎯ 104Ah Torque boost selection A041 R/W 00: Manual torque boost only 01: Simple torque boost ⎯ 1510h 2nd torque boost selection A241 R/W 104Bh Manual torque boost voltage A042 R/W 0 to 200 0.1 [%] 1511h 2nd manual torque boost voltage A242 R/W