4-2 Function Mode 4 Functions 4-96 Register No. Function name Parameter No. R/W Function Monitor or data range Resolution 104Ch Manual torque boost frequency A043 R/W 0 to 500 0.1 [%] 1512h 2nd manual torque boost frequency A243 R/W 104Dh V/f characteristics selection A044 R/W 00: VC 01: 1.7th power of VP 06: Special VP ⎯ 1513h 2nd V/f characteristics selection A244 R/W 104Eh Output voltage gain A045 R/W 20 to 100 1. [%] 1514h 2nd output voltage gain A245 R/W 1051h DC injection braking selection A051 R/W 00: Disabled 01: Enabled during stop 02:
Output frequency ⎯ 1052h DC injection braking frequency A052 R/W 0 to 600 0.1 [Hz] 1053h DC injection braking delay time A053 R/W 0 to 50 0.1 [s] 1054h DC injection braking power A054 R/W 0 to 100 1. [%] 1055h DC injection braking time A055 R/W 0 to 600 0.1 [s] 1056h DC injection braking method selection A056 R/W 00: Edge operation 01: Level operation ⎯ 105Ah Frequency upper limit A061 R/W 0.0/Frequency lower limit : A062 x 10 to Maximum frequency : A004 x 10 0.1 [Hz] 1517h 2nd frequency upper limit A261 R/W 0.0/2nd frequency lower limit : A262 x 10 to 2nd max. frequency : A204 x 10 0.1 [Hz] 105Bh Frequency lower limit A062 R/W 0.0/Starting frequency : b082 × 10 to Frequency upper limit :
A061 × 10 0.1 [Hz] 1518h 2nd frequency lower limit A262 R/W 0.0/Starting frequency : b082 x 10 to 2nd frequency upper limit : A261x10 0.1 [Hz] 105Dh 1060h 1063h Jump frequency 1 Jump frequency 2 Jump frequency 3 A063, A065, A067 R/W 0 to 4000 0.1 [Hz] 105Eh 1061h 1064h Jump frequency width 1 Jump frequency width 2 Jump frequency width 3 A064, A066, A068 R/W 0 to 100 0.1 [Hz] 1068h PID selection A071 R/W 00: Disabled 01: Enabled ⎯ 1069h PID P gain A072 R/W 2 to 50 0.1 106Ah PID I gain A073 R/W 0 to 1500 0.1 [s] 106Bh PID D gain A074 R/W 0 to 1000 0.1 [s] 106Ch PID scale A075 R/W 1 to 9999 0.01