3-7 Parameter List 3 Operation * 2nd control is displayed when SET (08) is allocated to one of from C001 to C005. 3-24 Parameter No. Function name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Page Characteristics, Torque boost A041 Torque boost selection 00: Manual torque boost only 01: Automatic (simple) torque boost 00 No - 4-12 A241 *2nd torque boost selection 00 A042 Manual torque boost voltage 0.0 to 20.0 5.0 Yes % 4-12 A242 *2nd manual torque boost voltage 0.0 A043 Manual torque boost frequency 0.0 to 50.0 2.5 Yes % 4-12 A243 *2nd manual torque boost frequency 0.0 A044 V/f characteristics selection 00: Constant torque characteristics (VC) 01:
Reduced torque characteristics (VP 1.7th power) 06: Special reduced torque characteristics (Special VP) 00 No - 4-12 A244 *2nd V/f characteristics selection 00 A045 Output voltage gain 20. to 100. 100. Yes % 4-12 4-76 A245 *2nd output voltage gain 100. 4-12 DC injection braking A051 DC injection braking selection 00: Disabled 01: Enabled 02: Frequency control [A052 set value] 00 No ⎯ 4-15 A052 DC injection braking frequency 0.0 to 60.0 0.5 No Hz 4-15 A053 DC injection braking delay time 0.0 to 5.0 0.0 No s 4-15 A054 DC injection braking power 0. to 100. 50 No % 4-15 A055 DC injection braking time 0.0 to 60.0 0.5 No s 4-15 A056 DC injection braking method selection 00: Edge operation 01:
Level operation 01 No ⎯ 4-15