EPSON — Print end

Print end [Input-Output] [Format] ^S(CNA, B, b [Parameter] [Function] “Print end” signal is set to the mode that is specified by parameter b. [Initial value] 0 [EX]"Print end" signal is set to the mode that is high in normal status, low in paper feeding. ^XA ^S(CNA,B,1 ^JUS ^XZ The ^JUS command is required to save settings to the non-volatile memory of the printer unit. Use a USB cable or Ethernet cable to send ESC/Label commands from the host PC. For the signal output timing, see "Timing chart" on page 20 . 8 Description Definition range b = mode D/E/N/0/1/2/3/4 Parameter b Mode description D/0 “Print end” signal is not output.

1 “Print end” signal is high in normal status, low in paper feeding. E/2 “Print end” signal is low in normal status, high in paper feeding. 3 “Print end” signal is high in normal status, when continuous printing end Low for 20 msec. N/4 “Print end” signal is low in normal status, when continuous printing end High for 20 msec.