omron — Test Run

5 Start Up „ Analog Monitor Output (H4- †† ) Use the H4- †† parameters to set up the output value of the analog monitor output and to adjust the output voltage levels. The default monitor value setting is “Output frequency”. ‹ Frequency Reference and Acceleration/ Deceleration Times „ Frequency Reference Setup(b1-01) Set parameter b1-01 according to the frequency reference used. „ Acceleration/ Deceleration Times and S-Curves There are two sets of acceleration and deceleration times which can be set in the C1- †† parameters. The default activated accel/ decel times are C1-01/02. Adjust these times to the appropriate values required by the application.

If necessary S-curves can be activated in the C2- †† parameters for softer accel/ decel start and end. ‹ Test Run Perform the following steps to start up the machine after all parameter settings have been done. 1. Run the motor without load and check if all input, outputs and the sequence work as desired. 2. Connect the load to the motor. 3. Run the motor with load and make sure that there is no vibrations, hunting or motor stalling occurs. After taking the steps listed above, the drive should be ready to run the application and per- form the basic functions. For details about more advanced setup refer to the technical man- ual.

20 I80E-EN J1000 Quick Start Guide b1-01 Reference source Frequency reference input 0 Operator keypad Set the frequency references in the d1-†† parameters and used digital inputs to switch over between different reference values. 1 Analog input Apply the frequency reference signal to terminal A1. 2 Serial Communica- tions Option RS232C or RS422/485 Memobus communication 3 Potentiometer Option Potentiometer Option