User Manual of EM760 High-Performance Inverter 6.9.1.3 Spindle application of machine tool F16.00=5: Machine tool spindle application The inverter can be used to configure the parameters ofthe corresponding function code for the application micro of machine tool spindle. 174 F04.00 Start-up method 0: direct start 1: start of speed tracking 1 O F04.08 Speed tracking mode Ones place: Tracking start frequency 1: stop frequency Tens place: Selection of search direction 1: Search in the opposite direction if the speed cannot be found in the command direction 11D O F04.19 Stop mode 0: slow down to stop 1: free stop 1 O F05.00 V/F curve setting 4:
square V/F 4 O F07.06 Bus voltage control options Ones place: Instantaneous stop/no-stop function options 1: deceleration Tens place: Overvoltage stall function options 1: valid 11 O F07.14 Number of retries after failure 0-20; 0: disable retry after failure 5 O F07.16 Interval of retries after failure 0.01~30.00 s 30.00 ● F17.01 VX2 virtual input function options The same as the function options of digital input terminal ofF02 group 51 O F17.28 Control options of virtual output terminal D7 D6 D5 D4 D3 D2 D1 D0 VY8 VY7 VY6 VY5 VY4 VY3 VY2 VY1 0: depending on the status of X1-X7 terminals 1:
depending on the output function status 11111101 B O Function code Function codename Parameter description Unit Current value of application macro Attribute F00.01 Drive control mode of motor 1 0: V/F control (VVF) 0 O