Appendix-1 Parameter List Appendix * 2nd control is displayed when '08 (2nd control)' is allocated to one of multi-function inputs from C001 to C006. App-10 Parameter No. Function name Monitor or data range (Digital Operator) Default setting Changes during operation Unit Set value Electronic thermal b012 Electronic thermal level 0.2 × Rated current to 1.2 × Rated current Rated current No A b212 *2nd electronic thermal level Rated current b013 Electronic thermal characteristics selection 00: Reduced torque characteristics 1 01: Constant torque characteristics 02:
Reduced torque characteristics 2 00 No b213 *2nd electronic thermal characteristics selection 00 Overload limit b021 Overload limit selection 00: Disabled 01: Enabled in acceleration/constant speed operation 02: Enabled in constant speed operation 01 No b221 *2nd overload limit selection 01 b022 Overload limit level 0.1 x Rated current to 1.5 x Rated current 1.5 × Rated current No A b222 *2nd overload limit level 1.5 × Rated current b023 Overload limit parameter 0.1 to 3000.0 1.0 No s b223 *2nd overload limit parameter 1.0 b028 Overload limit source selection 00: b022, b222 set values 01:
Input terminal FV 00 No b228 *2nd overload limit source selection 00 Lock b031 Soft lock selection 00: Data other than b031 cannot be changed when terminal SFT is ON. 01: Data other than b031 and the specified frequency parameter cannot be changed when terminal SFT is ON. 02: Data other than b031 cannot be changed. 03: Data other than b031 and the specified frequency parameter cannot be changed. 10: Data other than parameters changeable during operation cannot be changed. 01 No Others b080 AM adjustment 0. to 255. (Shared with C086 for AM offset adjustment) 100. Yes b082 Starting frequency 0.5 to 9.9 0.5 No Hz b083 Carrier frequency 2.0 to 14.0 5.0 No kHz