omron — Alarm Code Output (AC0 to AC3)

4-2 Function Mode Alarm Code Output (AC0 to AC3) •This function outputs a 3-bit or 4-bit code signal to indicate the cause of an Inverter trip. •If "01" (3-bit) or "02" (4-bit) is selected in alarm code selection C062, multi-function output terminals P1 to P3, or P1 to P4, are forced to output an alarm code. The following table shows the output alarm codes. 4 Functions 4-97 Parameter No. Function name Data Default setting Unit C062 Alarm code selection 00: Disabled 00  01: 3-bit code 02:

4-bit code Multi-function output terminals With 4-bit code selected With 3-bit code selected 14 13 12 11 Factor code Trip cause Factor code Trip cause AC3 AC2 AC1 AC0 0 0 0 0 Normal Normal Normal Normal 0 0 0 1 E01 to E03, E04 Overcurrent protection E01 to E03, E04 Overcurrent protection 0 0 1 0 E05, E38 Overload protection Overload protection in a low speed range E05 Overload protection 0 0 1 1 E07, E15 Overvoltage/Incoming overvoltage protection E07, E15 Overvoltage/Incoming overvoltage protection 0 1 0 0 E09 Undervoltage protection E09 Undervoltage protection 0 1 0 1 E16 Momentary power interruption protection E16 Momentary power interruption protection 0 1 1 0 E30 IGBT error E30 IGBT error 0 1 1 1 E06 Braking resistor overload protection  Other errors 1 0 0 0 E08, E11 E23, E25 EEPROM error, CPU error, GA communication error, Main circuit error   1 0 0 1 E10 CT error   1 0 1 0 E12, E13 E35, E36 External trip, USP error, Thermistor error, Brake error   1 1 0 0 E14 Grounding protection   1 1 0 1 E20 Abnormal temperature due to the cooling fin's speed drop 1 1 0 1 E21 Abnormal temperature   1 1 1 0 E24 Input phase loss protection   1 1 1 1 E50 to E79 Network error, Options 1, 2 Errors 0 to 9  