4-2 Function Mode Output Signal Logic Operation •This function performs output signal logic operations inside the Inverter. •All output signals are operation targets. However, the logic operation outputs (LOG1 to LOG6) are not subject to operations. 4 Functions •You can select from three types of operators (AND, OR, and XOR). •The setting parameters vary depending on the logic operation output selected. Refer to the following table to set the necessary parameters. 4-98 Parameter No. Function name Data Default setting Unit C021 to C025 Multi-function output terminal selection 33: LOG1 (Logic operation output [C142, C143, C144]) 34: LOG2 (Logic operation output 2 [C145, C146, C147]) 35:
LOG3 (Logic operation output 3 [C148, C149, C150]) 36: LOG4 (Logic operation output 4 [C151, C152, C153]) 37: LOG5 (Logic operation output 5 [C154, C155, C156]) 38: LOG6 (Logic operation output 6 [C157, C158, C159]) C026 Relay output (MA, MB) function selection 05 C142/C145/C148/ C151/C154/C157 Logic output signal selection 1 Select 00 to 50 from the multi-function output data (other than LOG1 to LOG6): Select operand 1. 00 C143/C146/C149/ C152/C155/C158 Logic output signal selection 2 Select 00 to 50 from the multi-function output data (other than LOG1 to LOG6): Select operand 2. 00 C144/C147/C150/ C153/C156/C159 Logic output signal operator selection 00: AND 01: OR 02:
XOR 00 Output signal 1 Output signal 2 LOGx (AND) LOGx (OR) LOGx (XOR) Selected signal Operand 1 selection Operand 2 selection Operator selection 33: Logic operation output 1 (LOG1) C142 C143 C144 34: Logic operation output 2 (LOG2) C145 C146 C147 35: Logic operation output 3 (LOG3) C148 C149 C150 36: Logic operation output 4 (LOG4) C151 C152 C153 37: Logic operation output 5 (LOG5) C154 C155 C156 38: Logic operation output 6 (LOG6) C157 C158 C159