omron — Extended Function Mode

3-7 Parameter List 3 Operation * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. 3-23 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Page Analog input, Others A005 FV/FI selection 00: Switches between FV/FI via terminal AT 01: Switches between FV/FE via terminal AT 02: Switches between FV/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 03: Switches between FI/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 04: Switches between FE/FREQ adjuster via terminal AT (Enabled only when 3G3AX-OP01 is used) 00 No  4-12 A006 FE selection 00:

FE only 01: FV/FI auxiliary frequency reference (not reversible) 02: FV/FI auxiliary frequency reference (reversible) 03: FE disabled 03 No  4-13 A011 FV start frequency 0.00 to 99.99 100.0 to 400.0 0.00 No Hz 4-14 A012 FV end frequency 0.00 to 99.99 100.0 to 400.0 0.00 No Hz A013 FV start ratio 0. to FV end ratio 0. No % A014 FV end ratio FV start ratio to 100. 100. No % A015 FV start selection 00: External start frequency (A011 set value) 01: 0 Hz 01 No  A016 FV, FE, FI sampling 1. to 30. 31. (with 500 ms filter ± 0.1 Hz hysteresis) 31. No  4-15 A017 Not used Use "00". * Do not change. 00 No  