omron — 6.1 - Software Settings for Trigger and External Strobe Output

6 - Sentech GigE and USB 3.0 IO and Power Connections AutoVISION/Visionscape supports both Trigger Input and Strobe Output for the Sentech STC-M cameras.  Line0 is used for the Trigger Input  Line1 is used for the Strobe Output  Both Trigger and Strobe Share IO Common Important: Please refer to the Sentech STC-M GigE and Sentech STC-M USB 3.0 camera manuals for the exact camera pin outs and for proper wiring instructions. GigE and USB 3.0 cameras are wired differently. Also, the STC-M[ ]S-231POE and STCMBE132POE GigE cameras do not follow the same wiring as the rest of the GigE cameras.

6.1 - Software Settings for Trigger and External Strobe Output Both AutoVISION and Visionscape FrontRunner allow the user to set up trigger input and strobe output. For AutoVISION, the Trigger should be set to Sensor 1 . The Lighting Mode should be set to Strobe 1 . For FrontRunner, the Trigger should be set to Sensor 1 . The External Strobe Control should be set to External 1 . AutoVISION FrontRunner Using Sentech STC-M Cameras with AutoVISION and Visionscape Page 24 of 35