3.5.2. Configuring the Camera Image Input AOS Set the imaging position, shutter speed, camera gain, and measurement range of Z so that the camera calibration target can be measured properly. Make sure that the warmup of the 3D vision sensor is completed before you perform the procedure below. 20 2 Hardware preparation: Place the camera calibration target so that the following conditions are met. • It is seen that the 3D vision sensor is placed directly above the center of the camera calibration target. • It is seen that the optical axis of the 3D vision sensor forms an angle of 90 ± 5 degrees with the plane of the camera calibration target. There are two methods of movement, for example. 1.