Victron Energy · VE.Bus BMS V2 · 26 стр.
Victron Energy VE.Bus BMS V2 User & Service Manual PDF (EN)
Оригинальное название: Victron Energy VE.Bus BMS V2 User & Service Manual PDF
Похожие инструкции
Содержание
Текст документа
Table of Contents
VE.Bus BMS V2 Table of Contents 1. General description .................................................................................................................. 1 2. Safety precautions ................................................................................................................... 3 3. Installation ............................................................................................................................. 4 3.1. What's in the box? ........................................................................................................... 4 3.2.
Basic installation ............................................................................................................. 5 3.2.1. Minimal VE.Bus firmware ......................................................................................... 5 3.2.2. Battery BMS cable connections ................................................................................. 6 3.2.3. Mains detector ..................................................................................................... 7 3.3. Controlling DC loads and chargers ........................................................................................ 8 3.3.1.
DC load control .................................................................................................... 8 3.3.2. DC charge control ................................................................................................. 8 3.3.3. Controlling inverter/chargers, solar chargers and other battery chargers .................................. 8 3.3.4. DVCC operation with VE.Bus BMS V2 ......................................................................... 9 3.3.5. Charger control via Charge disconnect ......................................................................... 9 3.3.6.
Charging with an alternator ...................................................................................... 9 3.4. Remote on/off terminal .................................................................................................... 10 3.5. GX device .................................................................................................................. 11 3.6. Connecting a Digital Multi Control or a VE.Bus Smart dongle ....................................................... 12 4. System examples .................................................................................................................. 13 4.1.
System with a GX device, on/off switch and pre-alarm circuit ........................................................ 13 4.2. System with a SmartShunt, BatteryProtect and solar charger ....................................................... 14 4.3. Basic system ............................................................................................................... 15 4.4. System with an alternator ................................................................................................ 16 4.5. Three-phase system with a Digital Multi Control ....................................................................... 17 5.
Operation ............................................................................................................................ 18 5.1. Important warning ......................................................................................................... 18 5.2. LED indications ............................................................................................................ 18 6. Updating the firmware ............................................................................................................. 19 6.1. Updating the firmware using VRM: Remote firmware update ........................................................ 19 6.2.
Updating the firmware using VictronConnect .......................................................................... 20 7. Frequently asked questions ...................................................................................................... 21 8. Technical specifications VE.Bus BMS V2 ..................................................................................... 22 9. Appendix ............................................................................................................................. 23 9.1. Dimensions VE.Bus BMS V2 ............................................................................................ 23 9.2.
VE.Bus BMS V2 compared to VE.Bus BMS V1 ....................................................................... 24
1. General description
VE.Bus BMS V2 1. General description The VE.Bus BMS V2 is a battery management system (BMS) for Victron Energy Lithium Battery Smart batteries available with a nominal voltage of 12.8V or 25.6V in various capacities. This is the safest of the mainstream lithium battery types. They can be connected in series, parallel and series/parallel so that a battery bank can be built for system voltages of 12V, 24V or 48V. Up to four 12.8V batteries or two 25.6V batteries can be connected in series. A total of 20 batteries can be connected, resulting in energy storage of up to 84kWh in a 12V system or up to 102kWh in a 24V and 48V system.
Protects each individual cell of a Victron Lithium Battery Smart (LiFePO ₄ ) battery Each individual cell of a LiFePO ₄ battery must be protected against under- and overvoltage, as well as low and high temperature. This is exactly what the VE.Bus BMS V2 does in combination with the battery's BTV module, which provides appropriate signals to the BMS. The Victron Lithium Battery 12.8V & 25.6V Smart have integrated Balancing, Temperature and Voltage control (acronym: BTV) and connect to the VE.Bus BMS V2 with two M8 circular connector cord sets. The BTVs of several batteries can be daisy chained. Please see our Lithium Battery Smart product page for details.
Depending on the signals from the battery, the BMS will: Generate a pre-alarm signal to warn of an imminent cell undervoltage. Shut down or disconnect loads in case of cell undervoltage. Turn off the inverter of VE.Bus inverter/chargers in case of cell undervoltage. Reduce the charge current in case of cell overvoltage or overtemperature of VE.Bus inverter/chargers or VE.Bus inverters. Shut down or disconnect battery chargers in case of cell overvoltage or overtemperature. Pre-alarm The pre-alarm output is normally free floating and becomes high in case of imminent cell undervoltage. It is set by default at 3.1V per cell and is adjustable on the battery between 2.85V and 3.15V per cell.
The minimum delay between pre-alarm and load disconnect is 30 seconds. Note that the pre-alarm does not generate a notification on the GX device and therefore not on VRM either. Load disconnect The Load disconnect output is normally high and becomes free floating in case of cell undervoltage. The Load disconnect output can be used to control: The remote on/off terminal of a load. The remote on/off terminal of an electronic load switch like a BatteryProtect (preferred low power consumption solution). Charge disconnect The Charge disconnect output is normally high and becomes free floating in case of cell over voltage or over temperature. The Charge disconnect output can be used to control:
The remote on/off terminal of a charger, like an AC charger, DC-DC charger or solar charger. A Cyrix-Li-Charge relay. A Cyrix-Li-ct Battery Combiner. LED indicators The BMS has the following LED indications: Status LED (blue): Lights once every 10 seconds when the Multi is switched on to indicate BMS info frames are being sent. When the Multi is off, either due to a low cell/remote off or just switched off by means off the front panel switch, the BMS goes into low power mode but continues to send BMS info frames (with a slightly longer interval between them). In this mode the BMS status led does not light up to conserve energy.
If the BMS is stuck in the bootloader, the status LED will flash rapidly. This can happen, for example, after an interrupted firmware update (to fix this, restart the update on VictronConnect or via VRM). Page 1 General description
1. General description
VE.Bus BMS V2 Cell voltage above 4V LED (red): Lights when the Charge disconnect output is low because of cell overvoltage or overtemperature. Cell voltage above 2.8V LED (blue): Lights when the Load disconnect output is high and the battery cell voltages are above 2.8V. Connectivity and communication with GX device On/off/charger-only control of VE.Bus products via a GX device. GX DVCC control of solar chargers. There is no need to install an BatteryProtect or Cyrix-Li-Charge to control solar chargers via the BMS like the VE.Bus BMS V1 does.
Has separate power input and output connections for GX devices The GX-Pow output supplies GX power from either the battery or from the Aux-In input, whichever voltage is higher. True remote on/off terminal The VE.Bus BMS V2 needs to remain connected to the battery positive in order to be able to keep the Multi in low power mode even when AC input on the Multi is available (Multi will stop inverting/charging, close the transfer switch and indicate a low battery error on the status LEDs). In comparison, disconnecting the battery positive of the VE.Bus BMS V1 only really turns the Multi off when no AC input is available.
Optional auxiliary power for remote access For users who want to ensure continued remote access via VRM even when the system is otherwise shut down (e.g. due to a battery undervoltage or inverter/charger shutdown), an AC-DC adapter (not provided by Victron) or other power supply can be connected to the Aux-In input. This keeps the GX device powered as long as auxiliary power is available, allowing for remote diagnostics if internet connectivity is still present. See the Technical specifications VE.Bus BMS V2 [22] for the required power rating of an AC-DC adapter. Page 2 General description
2. Safety precautions
VE.Bus BMS V2 2. Safety precautions Installation must strictly follow the national safety regulations in compliance with the enclosure, installation, creepage, clearance, casualty, markings and segregation requirements of the end-use application. Installation must be performed by qualified and trained installers only. Carefully study the product manuals of all connected devices before installing them. Switch off the system and check for hazardous voltages before altering any connection. Do not open the lithium battery. Do not discharge a new lithium battery before it has been fully charged first. Charge a lithium battery only within the specified limits.
Do not mount the lithium battery upside down or on its sides. Check if the lithium battery has been damaged during transport. Page 3 Safety precautions