Victron Energy · VE-Direct 120V/60Hz · 2 стр.

Victron Energy VE-Direct Inverters – New Models User Manual PDF (EN)

Оригинальное название: Victron Energy VE-Direct Inverters – New Models User Manual PDF

Читать онлайн

Похожие инструкции

Текст документа

New models: more power per kg and per dmі, and better high temperature performance. Please consult our price list for availability: https://www.victronenergy.com/information/pricelist VE.Direct communication port The VE.Direct port can be connected to: A computer (VE.Direct to USB interface cable needed) Apple and Android smartphones, tablets, MacBook’s and other devices (VE.Direct Bluetooth Smart dongle needed) Fully configurable: Low battery voltage alarm trip and reset levels Low battery voltage cut-off and restart levels Dynamic cut-off: load dependent cut-off level Output voltage 100 - 120V Frequency 60 Hz (50Hz up to 100V) ECO mode on/off and ECO mode sense level Monitoring:

In- and output voltage, % load and alarms Proven reliability The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature. High start-up power Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools. ECO mode When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.

Remote on/off A remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the two-pole connector. LED diagnosis Please see manual for a description. To transfer the load to another AC source: the automatic transfer switch For our low power inverters, we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.

DC connection with screw terminals No special tools needed for installation With Nema 5-15R or GFCI socket Inverter 12/375 VE.Direct Inverter 12/375 VE.Direct Nema 5-15R GFCI VE-Direct Inverters – new models VE-Direct Inverters – new models 250W – 1600W 120V www.victronenergy.com

Стр. 1

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands E-mail: sales@victronenergy.com www.victronenergy.com Inverter VE-Direct 120V/60Hz 12/1200 24/1200 48/1200 12/1600 24/1600 48/1600 12/250 12/375 12/500 12/800 24/250 24/375 24/500 24/800 48/250 48/375 48/500 48/800 Article number Nema 5-15R PINxx1250500 PINxx1370500 PINxx1500500 PINxx1800520 PINxx2122520 PINxx2161500 PINxx2161510 Article number GFCI PINxx1250510 PINxx1370510 PINxx1500510 PINxx1800530 PINxx2122530 Cont. power at 77 °F (25 °C) 250 W 375 W 460 W 800 W 1200 W 1500 W Cont.

power at 104 °F (40 °C) 200 W 300 W 380 W 650 W 1100 W 1350 W Time-limited power (cold start) 300 W/15s 450 W/10s 500 W/1h 900 W/1h 1300 W/1h 1700 W/1h Peak power 400 W/2s 600 W/2s 750 W/3s 1200 W/15s 1600 W/15s 2100 W/15s Output AC voltage (adjustable) / frequency 120 VAC +/- 3% 60Hz +/- 0,1% Input voltage range 9,2 - 17 / 18,4 - 34 / 36,8 – 62 V DC low shut down (adjustable) 9,3 / 18,6 / 37,2 V Dynamic (load dependent) DC low shut down Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff (fully configurable) DC low restart and alarm (adjustable) 10,9 / 21,8 / 43,6 V Battery charged detect (adjustable) 14 / 28 / 56 V Max.

efficiency 84 / 86 / 86 % 86 / 88 / 88 % 86 / 88 / 88 % 90 / 90 / 91 % 91 / 91 / 92 % 91 / 91 / 92 % Zero-load power 5 / 6 / 8 W 6 / 7 / 9 W 7 / 8 / 10 W 8 / 8 / 9 W 11 / 11 / 12 W 14 / 14 / 15 W Default zero-load power in ECO mode 1 / 1 / 2 W 1 / 1 / 2 W 1 / 1 / 2 W 1 / 2 / 2 W 1 / 2 / 3 W 1 / 2 / 3 W (default retry interval:

2,5 s, adjustable) ECO mode stop and start power setting Adjustable Protection (1) a - g Operating temperature range -40 °F to 149 °F (-40 to +65 °C) (fan assisted cooling) Derate 1,25% per °F above -104 °F (40 °C) Humidity (non-condensing) max 95% ENCLOSURE Material & Colour Steel chassis and plastic cover (blue Ral 5012) Battery-connection Screw terminals Maximum cable cross-section 10 mm² 10 mm² 10 mm² 25/16/16 mm² 35/25/25 mm2 50/25/25 mm2 1/4/4 AWG 8 AWG 8 AWG 8 AWG 4/6/6 AWG 2/4/4 AWG Standard AC outlets Nema 5-15R, GFCI Protection category IP 21 Weight (kg/lbs) 2,7 / 6 3 / 6,6 3,5 / 7,7 5,1 / 11 7 / 15 8 / 18 Dimensions (h x w x d, mm) ( h x w x d, inch) 86 x 165 x 260 86 x 165 x 260 86 x 172 x 275 95 x 231 x 334 117 x 231 x 374 117 x 231 x 395 Dimensions (h x w x d, mm) 86 x 165 x 260 86 x 165 x 260 86 x 172 x 275 105 x 216 x 310 117 x 231 x 333 117 x 231 x 365 86 x 165 x 260 86 x 165 x 260 86 x 172 x 275 105 x 216 x 310 117 x 231 x 333 117 x 231 x 365 ( h x w x d, inch) 3,4 x 6,5 x 10,2 3,4 x 6,5 x 10,2 3,4 x 6,8 x 10,8 3,7 x 9,1 x 13,0 4,6 x 9,1 x 14,7 4,6 x 9,1 x 15,6 3,4 x 6,5 x 10,2 3,4 x 6,5 x 10,2 3,4 x 6,8 x 10,8 4,1 x 8,5 x 12,2 4,6 x 9,1 x 13,1 4,6 x 9,1 x 14,4 3,4 x 6,5 x 10,2 3,4 x 6,5 x 10,2 3,4 x 6,8 x 10,8 4,1 x 8,5 x 12,2 4,6 x 9,1 x 13,1 4,6 x 9,1 x 14,4 ACCESSORIES Remote on-off Yes Automatic transfer switch Filax STANDARDS Safety EN-IEC 60335-1 / EN-IEC 62109-1 EMC EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3 1) Protection key:

a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) DC ripple too high Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm, and a relay for remote signalling. VE.Direct Bluetooth Smart BMV Battery Monitor The BMV Battery Monitor features an advanced microprocessor control system combined with high resolution measuring systems for battery voltage and charge/discharge current. Besides this, the software includes complex calculation algorithms to exactly determine the state of charge of the battery. The BMV selectively displays battery voltage, current, consumed Ah or time to go.

The monitor also stores a host of data regarding performance and use of the battery. Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm, and a relay for remote signalling. VE.Direct Bluetooth Smart dongle

Стр. 2