2009 — 150 Metri-Pack Connector Repair

HOME A.11 PACKARD 150 METRI-PACK CONNECTORS 150 METRI-PACK CONNECTOR REPAIR Inserting Socket Terminal General NOTE Metri-Pack connectors are embossed with the initials (P.E.D.). For wire location purposes, alpha characters are stamped into the socket housings. There are two types of connectors in this series: 1. See Figure A-38 for pull-to-seat connector or Figure A-39 for push to seat connector. Using a thin flat blade, like that on a hobby knife, carefully bend the tang outward away from the terminal body. • Pull-to-Seat • Push-to-Seat Separating Pin and Socket Housings Bend back the external latch slightly and separate the pin and socket halves of the connector. 2.

Gently pull or push on the lead to install the terminal back into the chamber. A click is heard when the terminal is properly seated. Mating Pin and Socket Housings 3. Gently pull or push on the lead to verify that the terminal is locked in place. Align the wire colors and push the pin and socket halves of the connector together. For push-to-seat: See Figure A-39 . Seat wires in separate channels of wire lock and then push channels inside chambers at wire end of socket housing. Fully installed, slot on each side of wire lock engages ear on socket housing. Removing Socket Terminal 1. See Figure A-38 for pull-to-seat connector or Figure A-39 for push to seat connector.

Remove wire lock (1) from wire end of socket housing on push-to-seat type connectors. NOTE For best results, free one side of wire lock first and then release the other side. 2. NOTE and are on the same side as the external latch. 3. (1/8 in.). a. For pull-to-seat: Stay between the terminal and the chamber wall and pivot the end of the pin toward the terminal body. b. For push-to-seat: There is a small opening for the pin. 4. When a click is heard, remove the pin and repeat the procedure. NOTE The click is the sound of the tang returning to the locked posi- tion as it slips from the point of the pin. 5.

Pick at the tang until the clicking stops and the pin seems to slide in deeper than it had previously. This is an indica- tion that the tang has been depressed. NOTE On those terminals that have been extracted on multiple occasions, the click may not be heard, but pivot the pin as if the click was heard at least 3 times. 6. Remove the pin. a. For pull-to-seat: Push on the lead to extract the ter- minal from the mating end of the connector. b. For push-to-seat: Pull on the lead to draw the ter- minal out the wire end. 2009 VRSC Service: Appendix A Connector Repair A-23 ng end of the con e middle of the ch rnal latch. chamber about nector. amber 3.2 mm