Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk CETOP Pneumatic Cylinder Type S Without Cushioning Ш 8mm - 12mm T echnical information Operating pressure: Single acting Ш8mm 2-10 bar/Ш10-12mm 1.5-10 bar Double acting Ш8-10mm 1.5-10 bar/Ш12mm 1.0-10 bar -20˚C...+70˚C Cr-Ni steel/Aluminium Cr-Ni steel Perbunan Shell Tellus C10 5 micron filtered, lubricated or non-lubricated compressed air. Temperature range: Housing/end caps: Rod: Seals: Lubricant: Operating medium: Other information: For ATEX certification use code "X" for example 23. X .151.XXX Sensors are available for this product, see data sheets TX1002/TX1003.
Mountings are available for this product, see data sheets MS1005. Double acting max stroke available 150 mm 150 mm 300 mm Minimum/maximum strokes apply, see table. Single Acting With Magnetic Piston Springs are designed for the return of the piston not the coupled mass. Double Acting With Magnetic Piston Area ratio (due to the reduction of the piston rod section). Ш8 4:3 Ш10 6:5 Ш12 4:3 To order: 23 . 151 .XXX 24.151 .XXX 25.151 .XXX 8 mm bore + stroke 1 0 mm bore + stroke 12 mm bore + stroke To order: 23 .
251 .XXX 24.251 .XXX 25.251 .XXX 8 mm bore + stroke 1 0 mm bore + stroke 12 mm bore + stroke Non-magnetic versions are also available, for example 2X.15.XXX Non-magnetic versions are also available, for example 2X.25.XXX Ш 8 mm 80 Ш 10 mm 50 F2 F1 F3 40 60 F2 F1 F3 F1 = single acting cylinders F2 = double acting cylinders in forward stroke 30 20 40 F3 = double acting cylinders in return stroke 10 1 2 3 4 5 6 7 8 9 10 20 N N bar 1 2 3 4 5 6 7 8 9 10 bar 120 F2 F1 F3 100 Ш 12 mm Document No:
IS003 Revision 2 60 80 F 20 40 N 1 2 3 4 5 6 7 8 9 10 bar F B Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Ø A B c D e F G J K L m sØ T V sW1 sW2 single acting max stroke available 8 12 M12x1.25 16 M4 12 15 M5 - 12 55 5 10 19 7 - 8 50 mm 10 12 M12x1.25 16 M4 12 15 M5 - 12 56 5 12 19 7 - 10 50 mm 12 17 M16x1.5 22 M6 16 20 M5 3.5 19.5 64 5 14 24 8 5 12 50 mm E C Single acting is rear ported only A M G A D G S SW1 J K V