Delta — Delta Electronics — инструкция

CANopen Slave Communication Module IFD9503 z Emergency object – EMERGENCY When IFD9503 detects an internal error, it will send an EMCY message to the CANopen bus. „ Format IFD9503 → master y Error register The value in the error register will be mapped to index address H’1001 in the object dictionary. Value = 0 indicates that no error occurs. Value = 1 indicates that a general error y Emergency error code takes place. Value = H’80 indicates that an internal error in the equipment occurs. Ќ Internal communication error This error indicates the communication error between IFD9503 and AC motor drive (e.g. communicate failure).

When such error occurs, the emergency error code will be H’8101, and the value in the error register will become 1. Ќ CANopen bus communication error This error indicates the communication error between CANopen master and IFD9503 slave (e.g. master disconnection). When such error occurs, the emergency error code will be H’8130, and the value in the error register will become 1. Ќ Insufficient length of PDO data This error indicates that the length of Receive PDO data actually sent out is shorter than the set data length. When such error occurs, the emergency error code will be H’8210, and the value in the error register will become 1.

Ќ Internal error in the equipment This error indicates the error taken place inside the AC motor drive (e.g. AC motor drive in low voltage). When such error occurs, the emergency error code will be H’FFXX (XX refers to the error code of the AC motor drive), and the value in the error register will become H’80. After the error is eliminated, the emergency error code will become H’0000. Ќ Eliminating error When an error is eliminated, the emergency error code will become H’0000. „ Explanation Take the IFD9503 slave of node ID = 6 as the object and compare the EMERGENGY messages sent out by IFD9503 in different error conditions.

y When in internal communication error y When in CANopen bus communication error DVP-PLC Application Manual 13 COB-ID Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 128(H’080) +Node-ID Emergency error code Error register 00 00 00 00 00 LSB MSB COB-ID Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 86 01 81 01 00 00 00 00 00