Iveco — 603.93.641-3Cp

DENOX 2 SYSTEM 257 T RAKKER E URO 4/5 Exhaust gas temperature sensor  Figure 10 102303 Figure 11 FUNCTIONAL WIRING DIAGRAM 102304 1. Supply voltage - 2. Variable output voltage - 3. Connector - 4. Signal cable (grey) - 5. Earth cable (white) - 6. Sensor. The function of this sensor is to send the control unit the catalyst inlet and outlet exhaust gas temperature values required to calculate the amount of urea to be injected into the system. Print 603.93.641 Base - November 2006