Iveco — 603.93.641-3Cp

Failing Type of Checks to be Measuring Values to be DTC FMI Visible failure Possible Cause Repair action Remarks component Failure performed conditions detected 16A INJECTOR One or more in- Possible injector Check wiring. CYLINDER jectors (bank 1 or connection Possible internal prob- 4 / OPEN bank 2) not oper- problem (or dis- lem also in ECM. CIRCUIT ating. connected inter- Replace the injector if nally). necessary. Possible prob- lem in control unit (capacitor). 16B INJECTOR One or more in- Possible injector Check wiring. CYLINDER jectors (bank 1 or connection Possible internal prob- 5 / OPEN bank 2) not op- problem (or dis- lem also in ECM. CIRCUIT erating.

connected inter- Replace the injector if nally). necessary. Possible prob- lem in control unit (capacitor). 16C INJECTOR One or more in- Possible injector Check wiring. CYLINDER jectors (bank 1 or connection Possible internal prob- 6 / OPEN bank 2) not oper- problem (or dis- lem also in ECM. CIRCUIT ating. connected inter- Replace the injector if nally). necessary. Possible prob- lem in control unit (capacitor). 16D COMPRES- Compression After carrying out the SION TEST Test in progress. compression test, turn IN PROG- the key OFF (after-run).

RESS DTC FMI Failing component Type of Failure Visible failure Possible Cause Repair action Checks to be performed Measuring conditions Values to be detected Remarks 16A INJECTOR CYLINDER 4 / OPEN CIRCUIT One or more in- jectors (bank 1 or bank 2) not oper- ating. Possible injector connection problem (or dis- connected inter- nally). Possible prob- lem in control unit (capacitor). Check wiring. Possible internal prob- lem also in ECM. Replace the injector if necessary. 16B INJECTOR CYLINDER 5 / OPEN CIRCUIT One or more in- jectors (bank 1 or bank 2) not op- erating. Possible injector connection problem (or dis- connected inter- nally). Possible prob- lem in control unit (capacitor).

Check wiring. Possible internal prob- lem also in ECM. Replace the injector if necessary. 16C INJECTOR CYLINDER 6 / OPEN CIRCUIT One or more in- jectors (bank 1 or bank 2) not oper- ating. Possible injector connection problem (or dis- connected inter- nally). Possible prob- lem in control unit (capacitor). Check wiring. Possible internal prob- lem also in ECM. Replace the injector if necessary. 16D COMPRES- SION TEST IN PROG- RESS Compression Test in progress. After carrying out the compression test, turn the key OFF (after-run).