Iveco — 603.93.641-3Cp

Failing Type of Checks to be Measuring Values to be DTC FMI Visible failure Possible Cause Repair action Remarks component Failure performed conditions detected 19A TURBINE Poor perform- Turbo sensor or Check turbine sensors SPEED EX- ance actuator may be and actuator (para- CEEDING faulty. meter acquisition). EVERY Air filter may be Check whether air filter PER- blocked. is blocked. MITTED RANGE 19B TURBINE Poor perform- Air filter blocked Check the air filter and IN OVER- ance or turbine rpm check parameters SPEED sensor signal im- linked with the turbine (THE plausible. by performing a road FAULT IS test (parameter acquisi- NOT DIS- tion).

PLAYED IF IT IS CAUSED BY A LOW ATMOS- PERIC PRESSURE) 19F NOx SEN- No effect per- Sensor signal im- Check the Nox sensor. SOR ceived by the plausible. ERROR driver. Nox sensor may be faulty. 1A5 TIMEOUT No effect per- Problems in the Check wiring. OF CAN ceived by the Denoxtronic Check and correct any MESSAGE driver. (on the CAN faults in the Denox- DM1DCU line). tronic control unit. 1A6 TIMEOUT No effect per- CAN configur- Check CAN line wiring. OF CAN ceived by the ation incorrect. Check Denoxtronic MESSAGE driver. CAN connec- control unit wiring and SCR1 tions defective. operation. Terminal resis- tance not suit- able.

1AE HUMIDITY No effect per- Sensorshort-cir- Check wiring SENSOR ceived by the cuited or faulty. Replace sensor if driver. necessary. DTC FMI Failing component Type of Failure Visible failure Possible Cause Repair action Checks to be performed Measuring conditions Values to be detected Remarks 19A TURBINE SPEED EX- CEEDING EVERY PER- MITTED RANGE Poor perform- ance Turbo sensor or actuator may be faulty. Air filter may be blocked. Check turbine sensors and actuator (para- meter acquisition). Check whether air filter is blocked.

19B TURBINE IN OVER- SPEED (THE FAULT IS NOT DIS- PLAYED IF IT IS CAUSED BY A LOW ATMOS- PERIC PRESSURE) Poor perform- ance Air filter blocked or turbine rpm sensor signal im- plausible. Check the air filter and check parameters linked with the turbine by performing a road test (parameter acquisi- tion). 19F NOx SEN- SOR ERROR No effect per- ceived by the driver. Sensor signal im- plausible. Nox sensor may be faulty. Check the Nox sensor. 1A5 TIMEOUT OF CAN MESSAGE DM1DCU No effect per- ceived by the driver. Problems in the Denoxtronic (on the CAN line). Check wiring. Check and correct any faults in the Denox- tronic control unit.

1A6 TIMEOUT OF CAN MESSAGE SCR1 No effect per- ceived by the driver. CAN configur- ation incorrect. CAN connec- tions defective. Terminal resis- tance not suit- able. Check CAN line wiring. Check Denoxtronic control unit wiring and operation. 1AE HUMIDITY SENSOR No effect per- ceived by the driver. Sensorshort-cir- cuited or faulty. Check wiring Replace sensor if necessary.