16/2 T RAKKER E URO 4/5 GEARBOXESZF 16 S 1620 T.D. - 2220 T.D. - 2520 T.O. OPERATION Slow range Figure 2/2 Pressurized air 119421 PNEUMATIC DIAGRAM FOR PRE-SELECTION IN SLOW RANGE The air from the services reservoir supplies the inhibitor valve (14) and the pre-selector (1) simultaneously, through the connecting pipe (15). At the sametime,the valve (6)moves and opens the passage for the air between the inlet duct (11) and the duct (3) connecting with the right-hand chamber of the cylinder of the splitter (2).
On shifting the pre-selector (1) downwards (position L of slow range), the air reaching the pre-selector (1) through the connecting pipe (16) supplies the double control valve (8). On pressing the clutch pedal, the air reaching the inhibitor valve (14) supplies the double control valve (8) through the connecting pipe (13). The pressurized air, supplying the above-mentioned valve (8), pushes the pistons (4 and 9) to the left. The movement of the pistons (4 and 9) makes it possible for the valve (7) to return to its seat and discharge the air contained in the left-hand chamber of the cylinder of the ksplittery (2) into the atmosphere through the connecting duct (12).
The air reaching the valve (8) passes through the inlet duct (11) and, finding the passage clear, supplies the right-hand chamber of the cylinder of the ksplittery (2) through the connecting duct (3). The piston ofthis cylinder, moving to the left, then drives the entire train downline, causing the slow range to be engaged. Print 603.93.641/A Revi - June 2007