Ethernet Communication Module IFD9506 Note: Once the password is locked, all the pages cannot be set up unless you unlock the password. However, if you set up IFD9506 by RS-232, you can return the setting to default one whether the password is locked or not. For example, if you have locked IFD9506 but forget the password, you have to return IFD9506 to default setting by RS-232, and all the settings will return to default ones. 8.10 Returning to Default Settings ones, check the “Factory Setting” box. If you need to clear all the settings after many modifications on the settings and return the settings to default ѓ Returning to default settings Check “Factory Setting” box and click on “Yes”.

Note: locked or not. It will take approximately 10 seconds to return to default settings, so DO NOT switch off If you set up IFD9506 by RS-232, you can return to settings to default ones whether the password is the power within the 10 seconds. Besides, you can also press “Reset” button for 2 seconds to return to default settings. 9 Webpage Settings This section introduces how to set up IFD9506 through webpages and explains how to set up columns in each page. IFD9506 is set up by UDP port 20006. Please be aware of the relevant settings for the firewall. 9.1 Webpage Connection „ Enable webpage function 1. Open the webpage browser and enter the IP address of IFD9506 in the address column. 2.

See below for the items to be set up. The block on the left hand side shows the basis status of IFD9506. DVP-PLC Application Manual 30