PROCESS UNIT hp Color 9850mfp 4.12 Replacing the 2nd transfer roller U A. Periodically replaced parts/cycle • 2nd transfer roller U: Every 200,000 copies B. Procedure 1. Remove the transfer belt. (See " 4.10 Replacing the transfer belt. ") 2. After raising the 2nd transfer roller U [1] once, remove it diagonally from the lower side. [2] Note: • The fixing of the 2nd transfer roller U was released when the transfer belt was removed at the time of the removal of the high voltage supply curler. • Be sure to reinstall the 2nd transfer roller U III DIS./ASSEMBLY so that the shaft end with a dent comes to the bottom. [1] 3. Remove 2 bearings [2] from the 2nd transfer 1 4.
Reinstall the above parts following the removal roller U [1]. steps in reverse. 2 [1] [2] 3-44