Q5690A PAPER FEED 2.3 Replacing the paper feed roller and the feed roller A. Periodically replaced parts/cycle • Paper feed roller: Every 600,000 copies (Every 500,000 copies in actual replacement count) • Feed roller: Every 600,000 copies (Every 500,000 copies in actual replacement count) B. Procedure 1. 2. Remove the HCI from the engine. Remove the paper feed pick-up cover B. 3. Remove the paper feed unit [1]. III DIS./ASSEMBLY [1] 4. Remove the bearing [1]. 5. Remove 2 stop rings [2] and then remove the 6. Remove the holder plate [4]. arm [3]. 7. Remove a stop ring [5]. 8. Remove the feed roller [6] and replace it with a 9. Remove the paper feed roller [7] and replace it new one.
[7] [4] [5] [3] [2] [1] with a new one. 10. Reinstall the above parts following the removal steps in reverse. [6] 3-7