HP — Interlock control

External section Composition Mechanisms Interlock control *1 Clearing paper jams Clear paper jams with the following procedure: Interlock control uses MS201 (PI interlock MS) that detects the opened upper tray. 1 Lift the release lever. 2 In that status, lift up the upper tray in a slanting direction. 1 Operation Top cover Release lever a Detecting the opened upper tray MS201 (PI interlock) is a switch for the interlock. When opening the upper tray of PI, MS201 goes off and 24V power from finisher CB is shut off. 2 Signals a Input signals 1 24V, 24V (finisher CB to PIDB) 3 Remove paper jams.

Input from a DC24V power source 8 Post insertion unit explanation ENWW Mechanism Method Clearing paper jams*1 Release lever 24V 24V FNS CB MS201 24V 24V PIDB