A+ SERVER 2042G-72RF4 USER'S MANUAL VT-UTF8 Combo Key Support Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/ VT100 terminals. Sredir Memory Display Delay Use this setting to set the delay in seconds to display memory information. Options are No Delay , 1 sec, 2 secs and 4 secs. Hardware Health Configuration CPU Overheat Alarm This setting allows you to specify the type of alarm for CPU overheating. Options include The Early Alarm and The Default Alarm . Other items in the submenu are systems monitor displays for the following information:
CPU1 ~ CPU4 Temperature, System Temperature, Fan 1-9 Reading, Chipset FAN1-2, CPU1 ~ CPU4 VCore, CPU1~4 DIMM Voltage, SR56x0 1.1V, +5V, +12V, 3.3Vcc, 3.3Vsb, Vbat. CPU Temperature Display (CTD) CPU Temperature descriptions are defined as: Low [Tctl Value = Lowest Value, Tctl Value = -45] Medium [Tctl Value = -46, Tctl Value = 60] High [Tctl Value = -61 and Above] Note: Only CPU temperature (Low, Medium, High) and system temperature (RT1) are required to be displayed in BIOS and in-system monitoring software. Other Motherboard components such as memory, chipset, SAS and 10Gb controllers, and others are not requried to display temperatures.
For debugging and testing purposes, BIOS and system monitoring software can show motherboard components’ temperatures (such as memory, chipset, SAS and 10Gb controllers). However for SMCI standard release version BIOS and system monitoring software, motherboard components’ temperatures are NOT required to be displayed. CPU Overheating Alarm (COA) CPU Overheating Alarm (COA) has “ Early Alarm ” and “ Default Alarm ” (default) options in the BIOS, and is required to be implemented in all fan speed control modes. 7-12