Chapter 5: Advanced Serverboard Setup BMC Jumper JPB1 is used to enable or disable theBMC (Baseboard Management Control) Chip and the onboard IPMI connection.This jumper is used together with the IPMI settings in the BIOS. The default position is on pins 1 and 2 to Enable BMC. See the table on the right for jumper settings. 5-9 Onboard Indicators LAN1/LAN2/LAN3/LAN4 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, one LED blinks to indicate activity while the other may be green, amber or off to indicate the speed of the connection. See the table on the right for the functions associated with the connection speed LED.
Dedicated IPMI LAN LEDs A dedicated IPMI LAN is also included on the H8QG7-LN4F serverboard. The amber LED on the right indicates activity, while the green LED on the left indicates the speed of the connection. See the table at right for more information. Power LED DP3 is an Onboard Power LED. When this LED is lit, it means power is present on the serverboard. Be sure to turn off the system and unplug the power cord(s) before removing or installing components.
5-23 BMC Jumper Enable (JPB1) Jumper Settings Jumper Setting Definition Pins 1-2 Enabled (default) Pins 2-3 Disabled LAN LED (Connection Speed Indicator) LED Color Definition Off 10 MHz Green 100 MHz Amber 1 GHz IPMI LAN Link LED (Left) & Activity LED (Right) Color Status Definition Green: Solid Link (Left) 100 Mb/s Amber: Blinking Activity (Right) Active Power LED (DP3) State System Status On Standby power present on motherboard Off No power connected