A+ Server 4020A-8R — A+ Server 4020A-8R User Manual: Comprehensive Guide for System Integrators

Chapter 3: System Interface Power Fail: Indicates a power supply module has failed. This should be accompanied by an audible alarm. A backup power supply module will take the load and keep the system running but the failed module will need to be replaced. Refer to Chapter 6 for details on replacing the power supply. This LED should be off when the system is operating normally. 3-4 SCSI Drive LEDs Each SCSI drive carrier has two LEDs. Green: When illuminated, the green LED on the front of the SCSI drive carrier indicates drive activity. A connection to the SCSI SCA backplane enables this LED to blink on and off when that particular drive is being accessed. Red:

A SAF-TE compliant backplane is needed to activate the red LEDs, which indicate a drive failure. Please refer to Chapter 6 for instructions on replacing failed SCSI drives. 3-5 LAN (Ethernet) Port LEDs The LAN Ethernet ports each have two LEDs. The yellow (left) LED indicates activity while the other (right) LED may be green, orange or off to indicate the speed of the connection. See the tables below for the functions associated with these LEDs. 3-3 Gb LAN Left LED Indicator Color Defi nition Off Not Active Yellow Active Gb LAN Right LED Indicator Color Defi nition Off No Connection Green 100 MHz Orange 1 GHz