Chapter 5: Advanced Serverboard Setup SCSI Termination Enable/ Disable Jumper JPA2 and JPA3 are used to enable or disable termination for the SCSI Channel A and B connectors, re- spectively. The default setting for both is open to enable termination. See the table on right for pin defi nitions. Note: In order for the SCSI drives to function properly, please do not change the default setting (enabled) set by the manufacturer. 3rd Power Supply Fail Signal Enable/Disable The system can notify you in the event of a power supply failure. This feature assumes that three redundant power supply units are installed in the chas- sis.
If you only have one or two power supplies installed, you should disable the function with the J3P header to pre- vent false alarms. See the table on the right for jumper settings. Watch Dog Enable/Disable JWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application hangs. Pins 1-2 will cause WD to reset the system if an applica- tion has frozen. Pins 2-3 will generate a non-maskable interrupt signal for the Note: When enabled, the user needs to application that is frozen. See the table on the right for jumper settings. Watch Dog must also be enabled in BIOS.
write their own application software in or- der to disable the Watch Dog Timer. 5-21 SCSI Term. Enable/Disable Jumper Settings (JPA2/JPA3) Jumper Setting Defi nition Open Enabled Closed Disabled 3rd Power Supply Fail Signal Jumper Settings (J3P) Jumper Setting Defi nition Open Enabled Closed Disabled Watch Dog Jumper Settings (JWD) Jumper Setting Defi nition Pins 1-2 Reset Pins 2-3 NMI Open Disabled