Chapter 6: Advanced Chassis Setup 6-2 Control Panel The front control panel must be connected to the JF1 connector on the serverboard to provide you with system status and alarm indications. A ribbon cable has bundled these wires together to simplify this connection. Connect the cable from JF1 on the serverboard (making sure the red wire plugs into pin 1) to the appropriate comnnector on the front control panel PCB (printed circuit board). Pull all excess cabling over to the control panel side of the chassis. The LEDs on the control panel inform you of system status – see Figure 6-2 for details. See Chapter 5 for details on JF1.
6-3 System Fans Three 9-cm chassis cooling fans (located in the center of the chassis) provide cooling airflow while three 8-cm exhaust fans expel hot air from the chassis. The fans should all be connected to headers on the serverboard (see Chapter 5). Each power supply module also has a cooling fan. Under normal operation all chassis fans, exhaust fans and the power supply fans run continuously. The chassis fans are hot-swappable and can be replaced without powering down the system. Fan Failure Replacing Chassis Fans Identifying the Failed Fan. 1. To locate and replace a failed chassis fan, begin by removing the top/left chassis cover (see Chapter 2 for details on removing the cover). 2.
Locate the fan that has stopped working. Removing a Hot-plug Fan Housing. 1. Depress the locking tab on the failed fan: on a chassis fan, puch the tab on the side of the housing inward, on the exhaust fan push down on the colored tab. 2. With the tab depressed, pull the fan straight out (see Figure 6-3). The wiring for these fans has been designed to detach automatically. 6-3