Supermicro AS-1041A-T2F — Supermicro A+ SERVER AS-1041A-T2F User's Manual (1U Rackmount) PDF

Chapter 5: Advanced Serverboard Setup Note: in single and dual-CPU confi gurations, memory must be installed in the DIMM slots associated with the installed CPU(s). Memory is limited to a maximum of 32 for single CPU and 64 GB for dual CPU confi gurations. To install the SNK-0022+ Passive Heatsink, use the following procedure: Installing a Passive Heatsink Installing a SNK-0022+ Passive Heatsink Note: Do not apply any thermal grease to the heatsink - the required amount has already been applied. Hold the heatsink and place the heatsink on top of the CPU so that the two 1. mounting holes are aligned with those on the retension mechanism.

Make sure the force of the screwdriver torsion is under 6.025 kgf-cm (5.23 2. lbs-in), and keep screw direction vertical. Screw in two opposite screws until they are just snug (do not fully tighten 3. them yet). Finish by fully tightening both screws after they are both in snug. 4. Note: see Chapter 6 for details on installing the air shroud. Removing the Heatsink Warning: We do not recommend removing the CPU or the heatsink. If you do need to remove the heatsink, please follow the instructions below to prevent damage to the CPU or other components. ! Removing a Passive Heatsink Unplug the power cord from the power supply. 1. Use your fi ngertips to gently press on the fastener cap.

Then turn it 2. counterclockwise for a 1/4 (90 0 ) turn and then pull the fastener upward to loosen it. Repeat Step 3 to loosen all fasteners from the mounting holes. 3. With all fasteners loosened, remove the heatsink from the CPU. 4. 5-5