A+ Workstation 4020C-T User's Manual 3rd Power Supply Fail Signal Enable/Disable The system can notify you in the event of a power supply failure. This feature assumes that three redundant power supply units are installed in the chas- sis. If you only have one or two power supplies installed, you should disable the function with the J3P header to pre- vent false alarms. See the table on the right for jumper settings. I 2 C to PCI Enable/Disable The JI 2 C1/2 pair of jumpers allows you to connect the System Management Bus to any one of the PCI expansion slots. The default setting is closed (on) for both jumpers to enable the connec- tion.

Both connectors must be set the same (JI 2 C1 is for data and JI 2 C2 is for the clock). See the table on right for pin defi nitions. Audio Enable/Disable Jumper JPAC is used to enable or disable the audio. Onboard audio is provided by AC '97 audio CODEC for high quality 6-channel (5.1) sound. The default setting is on pins 1-2 to enable the audio. See the table on right for pin defi nitions.

5-20 3rd Power Supply Fail Signal Jumper Settings (J3P) Jumper Setting Defi nition Open Disabled Closed Enabled I2C to PCI Enable/Disable Jumper Settings (JI2C1/2) Jumper Setting Defi nition Closed Enabled Open Disabled Audio Enable/Disable Jumper Settings (JPAC) Both Jumpers Defi nition Pins 1-2 Enabled Pins 2-3 Disabled