DeviceNet Slave Communication Module IFD9502 Instance1: In the table above, Data_in refers to the data transmitted from DeviceNet master to AC motor drive, and Data_out refers to the data transmitted from the AC motor drive to DeviceNet master.
DVP-PLC Application Manual 9 Attribute ID Access rule Name Data type 1 Get Revision UINT Attribute ID Access rule Name Data type Default 1 Get/Set Reset parameter USINT H’0000 2 Get/Set Length of input data USINT 2 words 3 Get/Set Length of output data USINT 2 words 11 Get/Set Data in [0] _ UINT H’2000 12 Get/Set Data in [1] _ UINT H’2001 13 Get/Set Data in [2] _ UINT H’FFFF 14 Get/Set Data in [3] _ UINT H’FFFF 15 Get/Set Data in [4] _ UINT H’FFFF 16 Get/Set Data in [5] _ UINT H’FFFF 17 Get/Set Data in [6] _ UINT H’FFFF 18 Get/Set Data In [7] _ UINT H’FFFF 25 Get/Set Data out [0] _ UINT H’2101 26 Get/Set Data out [1] _ UINT H’2102 27 Get/Set Data out [2] _ UINT H’FFFF 28 Get/Set Data out [3] _ UINT H’FFFF 29 Get/Set Data out [4] _ UINT H’FFFF 30 Get/Set Data out [5] _ UINT H’FFFF 31 Get/Set Data out [6] _ UINT H’FFFF 32 Get/Set Data out [7] _ UINT H’FFFF