Delta — Delta Electronics — инструкция

DeviceNet Slave Communication Module IFD9502 z Common Services 9. Class 0x96 PLC_Access z Class attributes z Instance 1 through 9 z Common Services z All instances in Class 0x96 do not support any Attribute.

DVP-PLC Application Manual 32 Attribute ID Access rule Name Data type Default 25 Get/Set Data out [0] _ UINT H’2101 26 Get/Set Data out [1] _ UINT H’2102 27 Get/Set Data out [2] _ UINT H’FFFF 28 Get/Set Data out [3] _ UINT H’FFFF 29 Get/Set Data out [4] _ UINT H’FFFF 30 Get/Set Data out [5] _ UINT H’FFFF 31 Get/Set Data out [6] _ UINT H’FFFF 32 Get/Set Data out [7] _ UINT H’FFFF Service code Implemented for Service name Class Instance 0x05 Yes Yes Reset 0x0E Yes Yes Get Attribute Single _ _ 0x10 No Yes Set Attribute Single _ _ Attribute ID Access rule Name Data type 1 Get Revision UINT Instance ID Description 1 S device of PLC 2 X device of PLC 3 Y device of PLC 4 M device of PLC 5 T device of PLC (bit device) 6 T device of PLC (word device) 7 C device of PLC (bit device) 8 C device of PLC (word device) 9 D device of PLC Service code Implemented for Service name Class Instance 0x32 No Yes Get PLC Data _ _ 0x33 No Yes Set PLC Data _ _