Single-axis controllers Wiring Devices in the range 145 ... 695 A (75 ... 400 kW) 4 4.6 4.6.5 General electrical data 1) Brake connection against control card of the controller Rated data Supply voltage 24 V 200 180 160 140 L max [m] 120 100 80 60 2.5 mm 2 (AWG 12) 40 1.5 mm 2 (AWG 14) 20 0.5 mm 2 (AWG 20) 0.75 mm 2 (AWG 18) 1 mm 2 (AWG 16) 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 I Br [A] L max Maximum brake cable length in [m] I BR Brake current in [A] U DC Supply voltage of the motor brake control E94AZHY004 4.6-31 EDS94SPP101 EN 3.1-04/2007 Operating frequency max. 6/min Operating times Can be ignored compared to the delay time of the brake. See documentation of the brake.
Service life > 10 millions of cycles Protection against Overload Short circuit of the terminals Polarity reversal at the input No Yes Yes Isolation 1) Double insulation (EN61800-5-1: Vrated = 300 V AC), Separation (UL: Vrated = 500 V AC) Voltage Current Power Breaking energy Type UDC [V] IDC [A] PDC [W] E [Ws] E94AZHY0101 18 ... 30 0.3 ... 5.0 max. 110 max. 10 U D U D = 2 C 4 V DC