Single-axis controllers Control terminals 4 4.7 Setting the supply voltage The supply voltage of the encoder must be adapted to the cable length. For this, use the parameter ”encoder voltage”, C00421. TTL Thalheim ITD21... 5,3 Sin-cos Thalheim ITD22... 5,3 Sin-cos (Hiperface) Sick/Stegmann Sin-cos (Endat) Heidenhain Tab. 4.7-1 KiMT Designation in the motor type code U r Rated encoder voltage The values listed in Tab. 4.7-1 are valid for the use of Lenze system cables at typical ambient temperatures. Other cables, other cable cross-sections or extreme ambient temperatures may require adaptations determined by means of measurements.
4.7-15 EDS94SPP101 EN 3.1-04/2007 Encoder Voltage setting [V] under C00421 Manufacturer KiMT Ur for cable length [m] Type [V] 0 - 10 10 - 30 30 - 50 50 - 70 70 - 90 90 - 10 0 100 -150 -Txx 5 ±5% 5.0 5.0 5.1 5.1 5.2 5.2 -S20 5 ±5% 5.0 5.0 5.1 5.1 5.2 5.2 SCS70 SCM70 SRS50 SRM50 -SCS -SC M -SRS -SR M 8 (7 ... 12) 8.0 ECN1313 EQN1325 EQI1329 -ECN -EQN -EQI 5 ±5% 5.0 5.1 5.2 5.3 5.4 5.5 5,7