Lenze — 6.6.4 Devices in the range 10 ... 36 A (4 ... 18 kW)

6 6.6 6.6.4 DC power supply modules Wiring Devices in the range 10 ... 36 A (4 ... 18 kW) 6.6.4 Devices in the range 10 ... 36 A (4 ... 18 kW) L1 L2 K1 L3 N PE F4 O K1 I R  E94AZPxxxxx K1 X109 X109 X110 X110 E94AxxExxxx  SSP94PSP21 Fig. 6.6-1 Example circuit for installation backplane and DC power supply module E94APNE0xx4 9400 DC power supply module E94AZPxxxxx Installation backplane E94AxxExxxx 9400 axis module F1 ... F4 Fuses Z1 Mains filter/RFI filter (optional) K1 Mains contactor RB Brake resistor c Alternative: mains connection at the bottom d 24 V supply voltage for control electronics according to IEC 61131-2  Tip!

Complete the wiring of the installation backplane before plugging in the standard device. The upper terminals of the installation backplane cannot be connected with a plugged-in standard device.  6.6-4 EDS94SPP101 EN 3.1-04/2007 L R R B L R 1 L2 L3 +UG -UG X111 3 +UG -UG  24E GE X11 E94APNE0xx4 X112 b1 Rb2 L1 L2 L3 b1 Rb2 L2 L3 24E GE X11