User Manual of A90 Series Inverter Select the final valid frequency setting channel and operation mode. F00.06=0: main frequency source A The final set frequency only depends on the main frequency source A. F00.06=1: auxiliary frequency source B The final set frequency only depends on the auxiliary frequency source B. F00.06=2: main and auxiliary operation results The final set frequency depends on the main and auxiliary operation results. Refer to the description of the function code F00.08. F00.06=3: switching between the main frequency source A and auxiliary frequency source B The final set frequency is determined by the status of the input function “26: Frequency source switching”:
invalid, depending on the main frequency source A; valid, depending on the auxiliary frequency source B. F00.06=4: switching between main frequency source A and main and auxiliary calculation results Frequency source switching”: invalid, depending on the main frequency source A; valid, The final set frequency is determined by the status of the input function “26: depending on the main and auxiliary operation results. Refer to the description of the function code F00.08. auxiliary operation results F00.06=5: switching between the auxiliary frequency source B and main and The final set frequency is determined by the status of the input function “26: Frequency source switching”:
invalid, depending on the auxiliary frequency source B; valid, depending on the main and auxiliary operation results. Refer to the description of the function code F00.08. 122 frequency source B 4: switching between main frequency source A and main and auxiliary operation results 5: switching between auxiliary frequency source B and main and auxiliary operation results Function Default Function code name Parameter description Unit Attribute code setting