sinee — A90 User Manual

User Manual of A90 Series Inverter Terminals”. Output frequency frequency of acceleration and deceleration time Fundamental Set frequency F15.09 0 Actual acceleration time Actual deceleration time time Set acceleration Set deceleration Time t time Fig. 7-32 Schematic Diagram of Acceleration and Deceleration Time As shown in Fig. 7-32, the acceleration time is defined as the time of acceleration from 0.00 Hz to the reference frequency of acceleration/deceleration time; and the deceleration time is defined as the time of deceleration from the reference frequency of acceleration/deceleration time to 0.00 Hz.

The actual acceleration/deceleration time varies according to the ratio between the set frequency and reference frequency. The reference frequency of acceleration/deceleration time is set by function code F15.09 that represents the reference frequency of acceleration/deceleration time. If F15.09=0, the reference frequency depends on the function code F00.16 (maximum frequency). Assuming F00.16=100.00Hz, the acceleration (deceleration) time is expressed as the time for the output frequency to increase (decrease) from 0.00Hz (100.00Hz) to 100.00Hz (0.00Hz).

232 Functio Parameter Default Function code name Unit Attribute n code description setting F15.10 Automatic switching of acceleration and deceleration time 0: Invalid 1: valid 0 ○ F15.11 Switching frequency of acceleration time 1 and 2 0.00 to maximum frequency F00.16 Hz 0.00 ● F15.12 Switching frequency of deceleration time 1 and 2 0.00 to maximum frequency F00.16 Hz 0.00 ●