User Manual of A90 Series Inverter 2.3 Installation Site Requirements and Management Attention 1. When carrying the inverter, hold its bottom. If you hold the panel only, the body main fall to hit your feet. 2. Install the inverter on non-flammable boards (e.g. metal). If the inverter is installed on a flammable object, a fire may occur. 3. When two or more inverters are installed in one control cabinet, please install a cooling fan and keep the air temperature below 50℃ at the air inlet. Overheating may cause fire and other accidents. 2.3.1 Installation site The installation site should meet the following conditions: 1. The room is well ventilated. 2.

The ambient temperature is -10°C to 50°C. 3. The controller should be free from high temperature and humidity (less than 90%RH) or rainwater and other liquid droplets. 4. Please install the inverter on a fire-retardant object (e.g. metal). Never install it on flammable objects (e.g. wood). 24 A90-4T045B A90-4T060 245 210/200 425 410 390 188 137 7.5 A90-4T075 A90-4T090 300 266 491 473 450 206 168 9 A90-4T110 A90-4T150 335 286 491 471 450 206 170 9 A90-4T176 335 286 623 601 570 293 248 11 A90-4T210 A90-4T253 400 330 743 723 690 300 246 13 A90-4T304