User Manual of A90 Series Inverter 70 motor speed) F01.23 Initial electrical angle of synchronous motor 0.0-359.9 (valid for synchronous motor) 0.0 ○ F01.24 ~F01.3 3 Reserved F01.34 Motor parameter self-learning 0: No operation 1: static self-learning of asynchronous motor 2: rotation self-learning of asynchronous motor 11: static self-learning of synchronous motor 2: rotary self-learning of synchronous motor 0 ○ F02 Input terminal function group F02.00 Options of X1 digital input function 0: no function 1: terminal running (RUN) 2: running direction (F/R) 3: stop control in three-line operation 4: forward jog (FJOG) 5: reverse jog (RJOG) 6: terminal UP 7: terminal DOWN 8:
clear UP/DOWN offset 9: free stop 10: reset fault 11: multi-segment speed terminal 1 12: multi-segment speed terminal 2 13: multi-segment speed terminal 3 14: multi-segment speed terminal 4 15: multi-segment PID terminal 1 16: multi-segment PID terminal 2 17: multi-segment torque terminal 1 18: multi-segment torque terminal 2 19: acceleration and deceleration 1 ○ F02.01 Options of X2 digital input function 2 ○ F02.02 Options of X3 digital input function 11 ○ F02.03 Options of X4 digital input function 12 ○ F02.04 Options of X5 digital input function 13 ○ F02.07 Options of AI1 digital input function 0 ○ F02.08 Options of AI2 digital input function 0 ○