User Manual of A90 Series Inverter 81 F05.18 Flux compensation gain of synchronous motor 0.00~500.00 % 0.00 ● F05.19 Filtering time constant of flux compensation of synchronous motor 0.00~10.00 s 0.50 ● F05.20 Change rate of VF separate power supply setting –50.00~50.00 % 0.00 ● F06 Vector control parameter group F06.00 Speed proportional gain ASR P1 _ 0.00-100.00 12.00 ● F06.01 Speed integral time constant ASR T1 _ 0.000-30.000 0.000: no integral s 0.200 ● F06.02 Speed proportional gain ASR P2 _ 0.00-100.00 8.00 ● F06.03 Speed integral time constant ASR T2 _ 0.000-30.000 0.000:

no integral s 0.300 ● F06.04 Switching frequency 1 0.00 to switching frequency 2 Hz 5.00 ● F06.05 Switching frequency 2 Switching frequency 1 to maximum frequency F00.16 Hz 10.00 ● F06.06 Separation threshold of speed loop integral 0.000-1.000 0.500 F06.07 Filtering time constant of speed loop output 0.000~0.100 s 0.001 ● F06.08 Vector control slip gain 50.00~200.00 % 100.00 ● F06.09 Upper limit source selection of speed control torque 0: set by F06.10 and F06.11 1: AI1 2: AI2 0 ○ F06.10 Upper limit of speed control motor torque 0.0~250.0 % 165.0 ● F06.11 Upper limit of speed control brake torque 0.0~250.0 % 165.0 ● F06.12 Excitation current proportional gain ACR-P1 0.00~100.00 0.50 ●