AH Motion Controller – Motion Control Instructions Manual *Note: _3 1. When one MC_MoveAbsolute instruction is executed but not finished yet, it is invalid to re-execute the instruction. Outputs Outputs Update Timing 3-44 Name Function Data type ( Setting value Timing for updating Default value) modulo/rotary axis. 4: mcCurrentDirection (1) BufferMode Specifies the buffering behavior of the instruction. eMC BUFF _ ER MODE* _ 0: mcAborting 1: mcBuffered 2: mcBlendingLow 3: mcBlendingPrevious 4: mcBlendingNext 5: mcBlendingHigh (0) When Execute shifts to True and Busy is False. Name Function Data type Output range (Default value) Done True when absolute target position is reached.
BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code when the error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done When the absolute positioning is completed. When Execute shifts to False. If Execute is False and Done shifts to True, Done will be True for only one period and immediately shift to False.
Busy When Execute changes to True. When Done shifts to True. When Error shifts to True. When CommandAborted shifts to True. Active When the motion on the axis is started When Done shifts to True. When Error shifts to True When CommandAborted shifts to True.