Delta Electronics AH — MC_MoveRelative

AH Motion Controller – Motion Control Instructions Manual *Note: 1. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations.  Outputs _3  Outputs Update Timing 3-54 Name Function Data type Setting value Timing for updating (Default value) BufferMode Specifies the buffering behavior of the instruction. eMC BUFF _ ER MODE _ 0: mcAborting 1: mcBuffered 2: mcBlendingLow 3: mcBlendingPrevious 4: mcBlendingNext 5: mcBlendingHigh (0) When Execute shifts to True and Busy is False. Name Function Data type Output range (Default value) Done True when relative distance is completed. BOOL True/False (False) Busy True when the instruction is executed.

BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done  When the relative positioning is completed.  When Execute shifts from True to False.  If Execute is False and Done shifts to True, Done will be True for only one period and immediately shift to False. Busy  When Execute changes to True.  When Done changes to True.

 When Error changes to True.  When CommandAborted shifts to True. Active  When the motion on the axis is started.  When Done changes to True.  When Error changes to True.  When CommandAborted shifts to True.  If Execute is False and Active shifts to