AH Motion Controller – Motion Control Instructions Manual *Note: 1. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations. Outputs _3 Outputs Update Timing 3-54 Name Function Data type Setting value Timing for updating (Default value) BufferMode Specifies the buffering behavior of the instruction. eMC BUFF _ ER MODE _ 0: mcAborting 1: mcBuffered 2: mcBlendingLow 3: mcBlendingPrevious 4: mcBlendingNext 5: mcBlendingHigh (0) When Execute shifts to True and Busy is False. Name Function Data type Output range (Default value) Done True when relative distance is completed. BOOL True/False (False) Busy True when the instruction is executed.
BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done When the relative positioning is completed. When Execute shifts from True to False. If Execute is False and Done shifts to True, Done will be True for only one period and immediately shift to False. Busy When Execute changes to True. When Done changes to True.
When Error changes to True. When CommandAborted shifts to True. Active When the motion on the axis is started. When Done changes to True. When Error changes to True. When CommandAborted shifts to True. If Execute is False and Active shifts to