Delta Electronics AH — MC_MoveAdditive

Chapter 3 Motion Control Instructions MC_MoveAdditive 3_  Inputs 3-61 FB/FC Description FB MC MoveAdditive controls the axis to move an additional distance at a given speed and acceleration. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Continuous Update Continuously updates Velocity when Continuousupdate is True BOOL True/False (False) When Active shifts to True and it will update continuously. Distance Relative distance to be moved. (Unit: user unit) LREAL Negative number, positive number or 0 (0) When Execute shifts to True and Busy is False. Velocity Target velocity.

(Unit: user unit/s) LREAL Positive number (0) When Execute shifts to True and Busy is False. Acceleration Acceleration rate. (Unit: user unit/s2) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Deceleration Deceleration rate. (Unit: user unit/s2) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Jerk Jerk value. (Unit: user unit/s3) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False.