Delta Electronics AH — MC_MoveAdditive

AH Motion Controller – Motion Control Instructions Manual Motion diagram: _3 - When M2( Execute ) changes to True, MC_MoveAbsoulte drives the axis to the commanded absolute position 7000. When M3( Execute ) changes to True at the position 4,500, the MC_MoveAbsoulte instruction is aborted and M23( CommandAborted ) changes to True. - Meanwhile, MC_MoveAdditive instruction is executed and adds relative distance 6500 on the previous commanded position 7000, and results the new commanded position 13500. - When the axis reaches 13500, M30( Done ) changes to True. - When M3( Execute ) changes to False, M30( Done ) changes to False.  Supported Products - AH Motion Controller CPU:

AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-70 Velocity 500 300 Time Position 13500 4500 2000 Time MC MoveAbsoulte _ M2(Execute) M20(Done) M21(Busy) M22(Active) M23(CommandAborted) M24(Error) MC MoveAdditive _ M3(Execute) M30(Done) M31(Busy) M32(Active) M33(CommandAborted) M34(Error) MC MoveAdditive _ M3(Execute) M30(Done) M31(Busy) M32(Active) M33(CommandAborted) M34(Error) MC MoveAbsoulte _ M2(Execute) M20(Done) M21(Busy) M22(Active) M23(CommandAborted) M24(Error)