Delta Electronics AH — MC_HaltSuperimposed

Chapter 3 Motion Control Instructions MC_HaltSuperimposed  Inputs 3_  Outputs 3-77 FB/FC Description FB MC HaltSuperimposed halts all superimposed motions of the axis without aborting the previous _ superimposed motion. Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Deceleration Deceleration rate. (Unit: user unit/s2) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Jerk Jerk value. (Unit: user unit/s3) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False.

Name Function Data type Output range (Default value) Done True when the superimposing effects is cleared. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Active True when the axis is being controlled. BOOL True/False (False) CommandAborted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code when the error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0)